狠狠噜天天噜日日噜视频麻豆,日韩国产成人AⅤ在线观看,国产九色视频在线观看,亚洲成a∨人片在线网

歡迎訪問安徽萬邦特種電纜官方網(wǎng)站,專業(yè)的電纜生產(chǎn)廠家!主營產(chǎn)品:扁電纜,拖鏈電纜,扁平電纜,螺旋電纜,聚氨酯電纜
服務(wù)咨詢熱線0550-7305800
熱門關(guān)鍵詞:
防火電纜
fanghuodianlan

防火系統(tǒng)專用電纜廠家

防火系統(tǒng)專用電纜
Special Cable For Fire Resistant System
本產(chǎn)品適用于0.6/1kv及以下的高層建筑物、地鐵、隧道、劇場、人防工程、石化系統(tǒng)等所作輸配電線路或火災(zāi)報警設(shè)備、通信設(shè)備等應(yīng)急設(shè)施的供電線路及 信號控制線路。電纜除低煙無鹵高阻燃特性外,還應(yīng)能處在火焰燃燒中正常運行180min,當火災(zāi)發(fā)生時,不發(fā)生短路和斷路故障,一直保障電力供給,維持系 統(tǒng)運行。并且燃燒時煙霧透光率高、毒性低,從而顯示其防火安全和消防救生的功能。
    It can be used not only to transmit and distribute power on the power line of 0.6/1kv voltage or below for high-rise building, subway, tunnel, theater, civil air defense engineering, petrochemical system, but also as power supply wire and signal control circuit of emergency facilities such as power transmission and distribution systems, fire alarm equipment and communications equipment and so on. Besides of features of LSZH and high flame resistance, it can also normally operate within 180min under the condition of flame burning. When the fire occurs, short-circuit and open circuit faults would not happen. It could endure continually supplying power and maintain the normal operation of system. During the process of burning, high light transmittance and low toxicity of cable can be considered as an evidence of functions of fireproofing safety and fire rescue.
一、產(chǎn)品執(zhí)行標準 Q/ZH09.06-2010
    Executive standard: enterprise standard
二、型號
    Type
    ZHT-FRVV—防火專用電纜
    ZHT-FRVV— type special cable for fire resistance

  • 使用特性

Characteristics
1、交流額定電壓:U0/U  0.6/1kv
A.C. rated voltage: U0/U  0.6/1kv
2、工作溫度:電纜導(dǎo)體長期工作溫度為70℃。
Long-term working temperature of cable conductor shall be 70℃.
3、敷設(shè)溫度:電纜敷設(shè)溫度不低于0℃。
Environment temperature for installation shall be no less than 0℃.
4、彎曲半徑:電纜彎曲半徑不低于電纜外徑的15倍。
Bending radium of cable shall be no less than 15 times that of cable outer diameter.
5、阻燃、耐火特性:符合GB19666-2005。
Flame resistance and fire resistance characteristics shall meet the requirements speculated in GB19666-2005 standard.

  • 性能參數(shù)表

    Performance parameter

項目
Item
單位
Unit
技術(shù)指標
Indices
20℃時導(dǎo)體直流電阻≤
Conductor DC Resistance at 20℃
Ω/KM截面
Cross section
1.01.52.54.06.0
電阻
Resistance
18.112.17.414.613.08
試驗電壓
Test voltage
V3.5KV,5min不擊穿。
Finished cable shall endure 3.5kv voltage test for 5 min without puncture.
絕緣電阻
Insulated resistance
10
耐火特性
Fire-resistant properties

A類(火焰溫度750試驗90min,2A 熔絲不斷)
Type A (flame temperature of 750 test 180min, 2A fuse continued)


  • 電纜示意圖

     The figure of cable structure




  • 注意事項

     Notes:
施工時嚴格防止電纜損傷,降低產(chǎn)品性能。
Cable damage and performance reduction are strictly prevented during installation.

  • 交貨要求

     Delivery requirement
允許根據(jù)雙方協(xié)議長度交貨;長度誤差不超過±5%。
Delivery length of cable depends on both agreements with length error allowance of ±5%.


標簽: 防火電纜  
相關(guān)內(nèi)容:防火電纜  
瀏覽:
返回頂部